Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Chinese Journal of Preventive Medicine ; (12): 1047-1058, 2023.
Article in Chinese | WPRIM | ID: wpr-985515

ABSTRACT

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Subject(s)
Pregnancy , Child , Humans , Female , Glycated Hemoglobin , Cohort Studies , Diabetes Mellitus/diagnosis , Sensitivity and Specificity , ROC Curve
2.
Journal of Preventive Medicine ; (12): 190-195, 2023.
Article in Chinese | WPRIM | ID: wpr-965458

ABSTRACT

Objective @#To investigate the effects of the exposure of sludge from sewage treatment plants and microplastic extracted from sludge on the oxidative stress levels in zebrafish, so as to put insights into the research into the impact of sludge and microplastics on human health. @*Methods @#Adult wild AB zebrafish were exposed to five groups of sludge (0, 12.5, 25, 50 and 75 g/L) and four groups of microplastics extract from sludge (0, 240, 480, 960/L), with 24 zebrafish in each group. The color, activity and death of zebrafish were observed every day. The contents of superoxide dismutase (SOD), catalase (CAT), glutathione (GSH) and malondialdehyde (MDA) were detected 0 h, 24 h, 48 h, 72 h, 96 h and 7 d post-exposure. A two-factor ANOVA was used to analyze the effects of different concentrations and time of exposure on the indicators above. @*Results @#Under 75 g/L sludge exposure, zebrafish began to show mortality at 72 h and all died after 7 d. The zebrafish in the other sludge groups and all microplastic groups had normal color and activity, and no mortality was observed. Sludge concentration interacted with exposure time to affect SOD, CAT, GSH and MDA (P<0.05). With increasing sludge concentration and exposure time, SOD decreased, MDA increased, CAT increased first and then decreased, GSH decreased first and then increased, and GSH continued to decrease since 24 h in the 75 g/L group. The microplastic concentration interacted with exposure time to affect SOD and GSH (P<0.05), but not CAT or MDA (P>0.05). With increasing microplastic concentration and exposure time, SOD and MDA increased, CAT increased first and then decreased, the GSH was slightly increased at 24 h and decreased after 72 h.@*Conclusion @#Both sludge and microplastics extracted from sludge can induce oxidative stress damage in zebrafish, and exposure time and concentration can interact to affect oxidative stress levels. The microplastics extracted from sludge have less effect on oxidative stress levels in zebrafish than sludge.

3.
Chinese Journal of Anesthesiology ; (12): 793-796, 2021.
Article in Chinese | WPRIM | ID: wpr-911278

ABSTRACT

Objective:To evaluate the relationship between preoperative cerebrospinal fluid/serum albumin ratio (Q-alb) and postoperative delirium (POD) in patients undergoing neuraxial anesthesia.Methods:The patients, aged 40-90 yr, of American Society of Anesthesiologists physical status Ⅰ or Ⅱ, underwent total knee/hip replacement under combined spinal-epidural block in our hospital from January 2018 to December 2020, were collected.After admission to the operating room, venous blood and cerebrospinal fluid samples were collected for determination of cerebrospinal fluid albumin, β-amyloid (Aβ) 1-42, Aβ 1-40, total tau protein (t-Tau), phosphorylated tau protein (p-Tau) and serum albumin levels (by enzyme-linked immunosorbent assay) and for calculation of Q-alb.When Q-alb was more than 10.2, the patient was considered to have blood-brain barrier disruption.Mini-Mental State Examination scale was used to evaluate the cognitive level on 1 day before surgery. The development of POD was evaluated using Confusion Assessment Method Chinese Reversion and Memorial Delirium Assessment Scale at 1-7 days after surgery.The patients were divided into POD group (P group) and non-POD (NP group) according to whether POD occurred.The receiver operating characteristic (ROC) curve was used to analyze the accuracy of Q-alb in predicting POD. Results:There were 49 cases in each group.Compared with group NP, concentrations of Aβ 1-42 and Aβ 1-40 were significantly decreased, concentrations of t-Tau and p-Tau albumin were increased, the ratio of Q-alb and blood-brain barrier disruption was increased in group P ( P<0.05). Before and after adjusting for confounding factors, Q-alb, cerebrospinal fluid Aβ 1-42, Aβ 1-40, t-Tau and p-Tau levels were risk factors for POD ( P<0.05). There was a positive linear regression relationship between Q-alb and levels of t-Tau and p-Tauin cerebrospinal fluid (t-Tau: β=0.587, P<0.001; p-Tau: β=0.427, P<0.001), and there was a negative linear regression relationship between Q-alb and levels of Aβ 1-42 and Aβ 1-40 in cerebrospinal fluid (Aβ 1-42: β=-0.762, P<0.001; Aβ 1-40: β=-0.531, P<0.001). There was no linear regression relationship between Q-alb and level of p-Tau in group P ( P=0.121). There was no linear regression relationship between Q-alb and level of Aβ 1-40 in group NP ( P=0.467). The results of ROC curve analysis showed that the area under the curve for Q-alb in predicting POD (95% confidence interval) was 0.827 (0.738-0.896). Conclusion:Preoperative higher Q-alb is the risk factor for POD in patients undergoing neuraxial anesthesia, and is more accurate in predicting POD.

4.
Chinese Journal of Anesthesiology ; (12): 406-410, 2021.
Article in Chinese | WPRIM | ID: wpr-911205

ABSTRACT

Objective:To evaluate the value of cerebrospinal fluid (CSF) nerve injury-related proteins levels in predicting postoperative delirium (POD) in patients.Methods:A total of 1 000 patients of both sexes, aged 40-90 yr, of American Society of Anesthesiologists physical status Ⅰ or Ⅱ, with Mini-Mental State Examination score>24 at 1 day before operation, undergoing elective knee/hip arthroplasty under spinal-epidural anesthesia , were enrolled in this study.Cubital venous blood samples were drawn before anesthesia for detection of the concentrations of plasma total cholesterol, high-density lipoprotein, low-density lipoprotein and triglyceride.CSF 2ml was extracted after successful spinal-epidural anesthesia puncture for measurement of concentrations of α-synuclein (α-syn), β-amyloid protein 1-40 (Aβ 1-40), Aβ 1-42, total-Tau (t-Tau), phosphorylated Tau (p-Tau), progranulin (PGRN) and soluble myeloid cell triggering receptor 2 (sTREM2) (by enzyme-linked immunosorbent assay). The Confusion Assessment Method was used at 1, 3 and 7 days after surgery to evaluate the occurrence of POD.The patients were divided into POD group and non-POD group according to whether POD occurred after operation.Logistic regression analysis was used to analyze the variables of which P values were less than 0.05 to analyze the risk factors for POD.The receiver operating characteristic (ROC) curve was drawn and area (AUC) under the curve was calculated to evaluate the accuracy of the related risk factors in predicting POD. Results:A total of 964 patients were enrolled in the study, and 108 patients were diagnosed with POD, and the incidence was 11.2%.The results of logistic regression analysis found that age and and increased α-syn in CSF concentration were risk factors for POD, and decreased PGRN in CSF concentration and Aβ 1-42/p-Tau in CSF were the protective factors for POD ( P<0.05). ROC curve analysis showed that α-syn (AUC 0.69, 95% confidence interval (CI) 0.634-0.748, sensitivity 57.41%, specificity 82.10%, Youden Index 0.3951), PGRN in CSF concentration (AUC 0.695, 95%CI 0.637-0.750, sensitivity 59.26%, specificity 80.86%, Youden Index 0.4012) and Aβ 1-42/p-Tau in CSF (AUC 0.635, 95%CI 0.574-0.692, sensitivity 93.52%, specificity 30.25%, Youden Index 0.2377) could predict the occurrence of POD. Conclusion:PGRN, α-syn concentration and Aβ 1-42/p-Tau in CSF can predict the occurrence of POD in patients.

5.
China Journal of Chinese Materia Medica ; (24): 981-999, 2021.
Article in Chinese | WPRIM | ID: wpr-878964

ABSTRACT

To evaluate the efficacy and safety of Chinese patent medicine in the treatment of knee osteoarthritis(KOA) with network Meta-analysis, and provide evidence-based medicine evidences for clinical practice. PubMed, Cochrane Library, EMbase, CNKI, Wanfang, VIP and CBM were used to search for clinical randomized controlled trials(RCTs) on Chinese patent medicines for treatment of knee osteoarthritis, with a time limit from the establishment of each database to March 2020. The bias risk assessment tool recommended by Cochrane was used to evaluate the quality of the included RCTs. The network Meta-analysis was performed by Stata 14.0 software. A total of 5 788 patients in 58 RCTs were included, involving 9 kinds of Chinese patent medicines. The results of the network Meta-analysis indicated that in terms of total effective rate, the top three optimal medication regimens were Jinwu Gutong Capsules + Amino Acid Glucose(AAG), Xianling Gubao + AAG and Biqi Capsules; the top three interventions to reduce the VAS score were Panlongqi Tablets > Xianling Gubao + AAG > Xianling Gubao + non steroidal anti-inflammatory drugs(NSAIDs); the top three interventions to reduce the total score of WOMAC were Jintiange Capsules+NSAIDs> Jinwu Gutong Capsules + AAG > Biqi Capsules + NSAIDs; the top three medication schemes with better curative effect to reduce Lequesnse index were Xianling Gubao + NSAIDs > Biqi Capsules + NSAIDs > Jintiange Capsules + NSAIDs; the top three interventions to reduce TNF-α level Xianling Gubao + AAG > Jintiange Capsules > Jintiange Capsules + AAG=Jinwu Gutong Capsules + AAG. In terms of safety, the top five interventions with the least adverse reactions were Biqi Capsules > Jinwu Gutong Capsules > Biqi Capsules + NSAIDs > Xianling Gubao + NSAIDs > Jintiange Capsules. The combined application of Chinese patent medicine and NSADIs or AAG can improve the clinical treatment effect and reduce adverse reactions in KOA patients.


Subject(s)
Humans , Biological Products , China , Drugs, Chinese Herbal , Network Meta-Analysis , Nonprescription Drugs , Osteoarthritis, Knee/drug therapy
6.
Chinese Journal of Tissue Engineering Research ; (53): 2414-2420, 2018.
Article in Chinese | WPRIM | ID: wpr-698717

ABSTRACT

BACKGROUND: Bone defects are one of the most important challenges that surgeons have to manage in total knee arthroplasty. The reasonable treatment method can guarantee the effect of the repair operation. OBJECTIVE: To review the relevant literatures concerning bone defects treated by primary total knee arthroplasty and revision total knee arthroplasty, and to analyze the optimal managements for different types of bone defects. METHODS: Relevant literatures were identified in China National Knowledge Infrastructure, Wanfang data, Vip, PubMed, Medline, and Web of Science. The key words were "total knee arthroplasty, total knee replacement, revision total knee arthroplasty, bone loss, bone defect, bone deficiency, management". The included studies were analyzed and summarized. RESULTS AND CONCLUSION: (1) Sixty-two studies regarding total knee arthroplasty for bone defects were included, without recognized standards on the type of bone defects. AORI is the most widely used classification for bone defects. (2) Pre-operated detailed evaluation including laboratory and radiographic examination, and accurate diagnosis are the key to success. (3) Management of bone defect was similar in tibia and femur, but there is still no standard classification and management of patellar bone defect. (4) Using stem fixation whenever a femoral or tibial component is revised can improve clinical outcome. (5) Through detailed evaluation, accurate diagnose and appropriate classification of bone defect, selection, according to the characteristics of different strategies, the age of the patient and the needs of life, can get a good clinical result.

7.
Journal of Preventive Medicine ; (12): 142-146, 2015.
Article in Chinese | WPRIM | ID: wpr-792376

ABSTRACT

Objective To understand the developmental effects induced by CdSe /ZnS quantum dots(QDs)on zebrafish embryos.Methods Zebrafish embryos were exposed to 0,0.5,1,2,4,8 and 16 nmol/L of CdSe /ZnS QDs,and the typical toxicological indexes were recorded at five time points respectively (24 hours post fertilization (hpf),48 hpf, 72 hpf,96 hpf,120 hpf).Results The results showed that the median lethal concentration (LC50 )for zebrafish embryos after 120 hpf was 21.38 nmol/L(95% CI =17.21 -26.57).The frequency of spontaneous movement in 60 seconds after 24 hpf,the frequency of heart beat in 60 seconds after 48 hpf,the hatching rate and the mortality rate were obviously affected by CdSe /ZnS QDs.Several abnormalities and toxic symptoms caused by CdSe /ZnS QDs at 8 nmol/L and 16 nmol/L were observed including pericardial edema,liver atrophy,non -depleted yolk,intestinal abnormal development and muscle degeneration after 120 hpf.Conclusion High level of CdSe /ZnS QDs (more than 8 nmol/L)could induce toxic effects on zebrafish embryonic development.

8.
Journal of Preventive Medicine ; (12): 998-1001, 2014.
Article in Chinese | WPRIM | ID: wpr-792344

ABSTRACT

Objective To evaluate acute toxicity and genotoxicity of sapindus saponin and to provide toxicological basis for sapindus saponin ’s daily applications. Methods Acute oral toxicity test,mammalian erythocyte micronucleus test, bacterial reverse mutation test and in vitro mammalian chromosome aberration test were used to investigate the effect of the sapindus saponin on gene mutation and chromosome aberration in both prokaryotic and eukaryotic cells. Results The acute toxicity test showed that the LD50 of sapindus saponin was 4640 mg/kg for both male and female mice. Toxic symptoms were observed including salivation,mucus and other toxic manifestations. There was no significant difference between the each dose group and the negative control group in the results of mammalian erythocyte micronucleus test( P>0. 05). The results of bacterial reverse mutation test were also negative. In each dose group and strain with or without S9,the number of revertant colonies did not exceed 2 times than that of spontaneous revertant colonies( negative control). No dose-response relationship was observed. The vitro mammalian chromosome aberration test showed that the IC50 of sapindus saponin on CHL was 75 μg/ml,and the differences between each dose group and the negative control group were not statistically significant( P >0. 05 ). However,the positive control group differed from the negative control group in all tests( P <0. 01). Conclusion Under this experimental condition,sapindus saponin has no genotoxicity.

9.
Arq. bras. oftalmol ; 75(2): 116-121, mar.-abr. 2012. graf, tab
Article in English | LILACS | ID: lil-640158

ABSTRACT

PURPOSE: To evaluate the differences of wavefront aberrations under cycloplegic, scotopic and photopic conditions. METHODS: A total of 174 eyes of 105 patients were measured using the wavefront sensor (WaveScan® 3.62) under different pupil conditions: cycloplegic 8.58 ± 0.54 mm (6.4 mm - 9.5 mm), scotopic 7.53 ± 0.69 mm (5.7 mm - 9.1 mm) and photopic 6.08 ± 1.14 mm (4.1 mm - 8.8 mm). The pupil diameter, standard Zernike coefficients, root mean square of higher-order aberrations and dominant aberrations were compared between cycloplegic and scotopic conditions, and between scotopic and photopic conditions. RESULTS: The pupil diameter was 7.53 ± 0.69 mm under the scotopic condition, which reached the requirement of about 6.5 mm optical zone design in the wavefront-guided surgery and prevented measurement error due to the pupil centroid shift caused by mydriatics. Pharmacological pupil dilation induced increase of standard Zernike coefficients Z3-3, Z4(0) and Z5-5. The higher-order aberrations, third-order aberration, fourth-order aberration, fifth-order aberration, sixth-order aberration, and spherical aberration increased statistically significantly, compared to the scotopic condition (P<0.010). When the scotopic condition shifted to the photopic condition, the standard Zernike coefficients Z4(0), Z4², Z6-4, Z6-2, Z6² decreased and all the higher-order aberrations decreased statistically significantly (P<0.010), demonstrating that accommodative miosis can significantly improve vision under the photopic condition. Under the three conditions, the vertical coma aberration appears the most frequently within the dominant aberrations without significant effect by pupil size variance, and the proportion of spherical aberrations decreased with the decrease of the pupil size. CONCLUSIONS: The wavefront aberrations are significantly different under cycloplegic, scotopic and photopic conditions. Using the wavefront sensor (VISX WaveScan) to measure scotopic wavefront aberrations is feasible for the wavefront-guided refractive surgery.


OBJETIVO: Avaliar as diferenças de aberrações de frente de onda, em diferentes condições pupilares: sob cicloplegia, escotópica e fotópica. MÉTODOS: Um total de 174 olhos de 105 pacientes foram avaliados utilizando o sensor de frente de onda (WaveScan® 3.62) em diferentes condições pupilares: sob cicloplegia 8,58 ± 0,54 mm (6.4 mm-9.5 mm), escotópica 7,53 ± 0,69 mm (5,7 mm - 9,1 mm) e fotópica 6,08 ± 1,14 mm (4,1 mm - 8,8 mm). Diâmetro da pupila, coeficientes de Zernike, RMS ("Root Mean Square") das aberrações de alta ordem e as aberrações dominantes foram comparados entre as condições sob cicloplegia e escotópica, e entre as condições escotópica e fotópica. RESULTADOS: O diâmetro da pupila foi 7,53 ± 0.69 mm sob a condição escotópica e atingiu a exigência de cerca de 6,5 mm de zona óptica na cirurgia baseada em análise de frentes de ondas, evitando erros de medição consequentes à mudança de centroide pupilar provocada por midriáticos. A dilatação farmacológica da pupila induziu aumento dos coeficientes de Zernike Z3-3, Z4(0) e Z5-5. As aberrações de mais alta ordem (terceira, quarta, quinta e sexta ordem) e a aberração esférica aumentaram de forma estatisticamente significativa, em comparação com a condição escotópica (P<0,010). Quando a condição escotópica se mudou para a condição fotópica, os coeficientes de Zernike Z4(0), Z4², Z6-4, Z6-2, Z6² e todas as aberrações de alta ordem diminuíram de forma estatisticamente significativa (P<0,010), demonstrando que a miose acomodativa pode significativamente melhorar a visão sob a condição fotópica. Sob as três condições, a aberração coma vertical apareceu mais frequentemente dentro das aberrações dominantes, sem influência significativa da variação do tamanho da pupila, e a proporção de aberração esférica diminuiu com a diminuição do tamanho da pupila. CONCLUSÕES: As aberrações de frente de onda são significativamente diferentes sob cicloplegia, condições escotópica e fotópica. O uso do sensor de frentes de onda (VISX WaveScan) para medir as aberrações de frente de onda escotópicas é uma opção viável para a cirurgia refrativa baseada em análise de frentes de onda.


Subject(s)
Adolescent , Adult , Humans , Young Adult , Accommodation, Ocular/physiology , Contrast Sensitivity/physiology , Corneal Wavefront Aberration/diagnosis , Ophthalmoplegia/physiopathology , Corneal Topography , Corneal Wavefront Aberration/physiopathology
10.
Chinese Journal of Surgery ; (12): 495-498, 2005.
Article in Chinese | WPRIM | ID: wpr-264480

ABSTRACT

<p><b>OBJECTIVE</b>To shorten the time of external skeletal fixation on legs, and enhance quality of limb lengthening, avoid complications of shortening, bending, twisting and etc.</p><p><b>METHODS</b>Insert pin transcortical to attack external skeletal fixation simultaneously, put un-reaming locked intramedullary nail (do not insert distal locked screw) into endosteum of lengthening bone. After the legs achieved predetermined length, insert distal locked screw and then remove external skeletal fixation, locked intramedullary nail, then maintain consolidation of rehabilitation.</p><p><b>RESULTS</b>The group lengthened legs for 412 cases. The range of lengthening was 3 to 18 cm. Mean length was 7.6 cm. The mean time for needed external skeletal fixation was 20 d/cm. The mean time of osteogenesis was 56 d/cm. For complications, there were 3 tibias ununion cases and 1 varus ankle. All cases were treated undergoing twice.</p><p><b>CONCLUSIONS</b>The method reduces the time for needed external skeletal fixation visibly, enhances the quality of limb lengthening remarkably, prevents complications of shortening new bone, deformity, bending and re-fracture which do not effect the healing time. This is a new choice of limb lengthening.</p>


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Bone Lengthening , Methods , Bone Nails , Follow-Up Studies , Fracture Fixation, Intramedullary , Ilizarov Technique , Tibia , General Surgery , Treatment Outcome
11.
Chinese Journal of Surgery ; (12): 1157-1160, 2004.
Article in Chinese | WPRIM | ID: wpr-345109

ABSTRACT

<p><b>OBJECTIVE</b>To study the role of the synchronized springy lengthening apparatus for the tibia and calcaneal tendon designed by the author in preventing the clubfoot of secondary to the Ilizarov tibia lengthening.</p><p><b>METHODS</b>Based on the Ilizarov tibia lengthening apparatus, a special synchronized springy lengthening apparatus for the tibia and calcaneal tendon was designed. The tibial was made of distal and proximal 2 rings respectively and 4 threaded rods, and the calcaneal was made of a half ring, 2 hinges and a threaded rod with spring. The half ring was fixed to the calcaneus by 2 crossed wires. The fracture tibia and fibula, ankle joint, talocalcaneal joint were attached to the apparatus. At the same time of tibia lengthening, the soft tissue was simultaneously stretched, the ankle joint could move, and the leg could bear weight. If the clubfoot angle was larger, the percutaneous fasciotomy of calcaneal tendon was performed; if the angle was less than 20 degrees, the pes deformities were corrected only by the stretch of calcaneal tendon.</p><p><b>RESULTS</b>Seventy-seven patients' tibia were lengthened averagely 4.6 cm, with an average speed of 0.7 mm/d. The healing made tibia lengthened, and the index was 1.35 months/cm. There were not the secondary varus and valgus deformities and clubfoot in all the patients. The clubfoot with 100-400 angle of the 16 patients were corrected after tibia lengthening.</p><p><b>CONCLUSIONS</b>The new apparatus coincides with the biomechanical principle and can effectively prevent the secondary deformities of foot such as clubfoot, talipes varus and valgus after tibia lengthening procedure.</p>


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Bone Lengthening , Methods , Equipment Design , Leg Length Inequality , General Surgery , Treatment Outcome
12.
Journal of Environment and Health ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-545978

ABSTRACT

Objective To understand the effect of the organic extracts of tap water deeply treated with O3-BAC on DNA damage. Methods During June to July 2005, water samples were collected from 6 sites in waterworks A treated with O3-BAC, the raw water, the pre-chlorination water, the filtration water, the post-ozonation water, the BAC water and the tap water respectively and 4 sites in waterworks B treated by general treatment, the raw water, the pre-chlorination water, the filtration water, and the tap water respectively. The test was carried out on extracts of water sample from waterworks A with dosage(7.00, 3.00, 1.50, 1.00, 0.75, 0.38 L/plate)and waterworks B with dosage(7.00, 3.00, 1.00 L/plate)using S.typhimurium strains TA98 and TA100. Cytokinesis-blocked micronucleus (CBMN) test, Comet assay were used on extracts of water sample from waterworks A with dosage(3.00, 1.50, 0.75, 0.38 L/plate). Human embryo lung fibroblast (KMB17 strain) p53 ELISA were used with dosage(3.00, 1.00, 0.3 L/plate). Results Ames test showed that in the waterworks A, at the dose of 7.0 L, the revertants of the raw water, pre-chlorination water, the filtration water on TA98-S9 and 7.0 L, 3.0 L/plate, the revertants of the raw water, pre-ozonation water, filtration water on TA98+S9 were twice more than that of solvent control; in waterworks B, at the dose of 7.0 L/plate, the revertants of the raw water, pre-chlorination water, filtration water on TA98-S9 and 7.0 L, 3.0 L/plate the revertants of the tap water on TA98-S9, and 7.0 L/plate pre-chlorination water on TA98+S9 were twice more than that of solvent control. Cytokinesis-blocked micronucleus (CBMN) test showed that in waterworks A, at the dose of 3.0 L/plate, the micronucleus rates of the raw water, filtration water were significant high than that of solvent control(P

SELECTION OF CITATIONS
SEARCH DETAIL